Anritsu/Wiltron 68369B

$7,950.00

Freshly Aligned/Calibrated – “basic” calibration was done in our lab

1 in stock

Description

Anritsu 68369B w/ Options 2B,11 – 40GHz Signal Generator – Calibrated and TESTED!  – Cleaned Up

(Same specs as 68369A/NV or 68369C w/ 2B,11. )

 
Pictures are from of a similar item we sold recently.  Item you will receive will be in similar physical condition, with same specs and fresh alignment + basic calibration (details below.)
 
We also have the A/NV and “C” versions of these – let us know if you need those instead.

 
7 day right of refusal and 30 day warranty – so bid with confidence!  –  All international sales are final.

We can ship this item world-wide and can work with the customer to arrange shipping.  We can use your shipping account, or you can arrange for the item to be picked up, or we can send you the estimated shipping cost via FedEx etc.
Why Buy From Us:
  • Repair/Calibration Services: We can re-align (the YIG and other critical components in) and repair these signal generators at very reasonable prices. We have a number of these Anritsu/Wiltron signal generators, with some units dedicated as “parts” units.   We can also do basic frequency accuracy and frequency response flatness calibration over the entire 40-GHz range (see details below.)
  • Warranty/Exchange/Loan/Rental: We offer warranty, and can also offer free replacement/exchange in case of issues.  We can also offer “loaner” units while your unit is being evaluated for repair, if needed, at reasonable costs.
Freshly Aligned/Calibrated – “basic” calibration was done in our lab and here are the details:
  • Frequency Accuracy Calibration: Internal 100MHz Reference Oscillator was calibrated using a GPS Disciplined Frequency Standard driving a 26 GHz frequency counter.  This was used to obtain a frequency counter reading of exactly 10 GHz for a 10 GHz RF output frequency.
  • YTO (Yig Tuned Oscillator) Adjustments: YTO and other adjustments were made for:
    • Coarse Tuning
    • Fine Tuning
    • Frequency Offset
    • YIG Linearization
    • FM Coil
    • Ramp Center
    • Sweep Width
    • Center Frequency
  • Frequency Response Calibration: Using a 10MHz to 40GHz power sensor/meter setup (NIST traceable) frequency response (amplitude vs frequency) was calibrated and saved into a user-level setting.
  • Testing/Validation:  Finally, the signal generator was extensively tested over the full frequency range for both CW and Sweep (both Analog Sweep and Step Sweep) – see pics –  Also, tested over the full power level range of the attenuator, and the 0.1 Hz frequency resolution.
(We calibrate the signal generator in our lab using NIST traceable equipment.  However, we are not a certified calibration lab.)
 
 
Key Features
  • Extensively tested over various frequencies from 10MHz to 40GHz and power levels, CW as well as sweep modes (see pics)
  • Has been thoroughly cleaned up – there are however some scuffs/marks, paint chips and/or sticker residue (see pics)
Options 
  • 2B: 110 dB Step Attenuator. Adds a 10 dB per step attenuator with a 110 dB range for models having a high-end frequency of 40 GHz.
  • 11:  0.1 Hz Frequency Resolution over the full 40 GHz range.
Shipping
We normally ship via FedEx, but will choose UPS or USPS if we think that is more appropriate for a particular package.  We normally insure items over $250 in value, and require a signature on delivery.
Note that the shipping cost includes the estimated insurance cost for this item.

Included Accessories 

This sale does not include probes, cables, manuals, power cords or any other accessories.  Spectrum Analyzer shown in the pictures is only for demonstration purpose and not included in this auction.  Only the item in the title of this listing is part of this sale.
7 day right of refusal and 30 day warranty.  Item must be in the same condition for any returns – calibration or warranty stickers must not have been tampered with.  All international sales are final.
 
Please note that shipping and insurance costs are non-refundable.  
 
Feedback is very important to me and I strive for 100% positive on every transaction. If you are unsatisfied with any aspect of your transaction, please contact me before leaving negative or neutral feedback so that I can address and remedy the issue immediately. Additionally, I am always happy to leave positive feedback for our trading partners after a successful transaction. 